REDUCTION OF COD FROM SIMULATED WASTEWATER BY FABRICATED HYDROPHOBIC MEMBRANE

Authors

  • Nidaa Adil Jasem Highway and Transportation Dep, College of Engineering, Al-Moustansirya University

DOI:

https://doi.org/10.30572/2018/KJE/821168

Keywords:

COD, Membrane, Hydrophobic, wastewater

Abstract

Hydrophobic membrane was fabricated using 15% of Polysulfone (PSF) as a polymer and 85% of dimethylformamide (DMF) as a solvent by phase inversion method. Distilled  water was used to test water flux and membrane permeation. Scanning electron microscope was used to study the structural changes on the membrane surface. Synthetic wastewater was used to test the efficiency of the hydrophobic membrane. Membrane efficiency examined by chemical oxygen demand (COD) percentage removal. The results showed that the pure water flux dropped from 85 L/m2.hr to 75 L/m2.hr. for the first run and from 86 L/m2.hr to 82 L/m2.hr for the second and third runs. For synthetic wastewater the flux dropped from 75 to 38 L/m2.hr, 75 L/m2.hr to 52 L/m2.hr and 75 to 45 L/m2.hr for the first, second and third runs, respectively. Removal efficiency of COD was 90% after 10 days, then it dropped down to 70 %, after cleaning the membrane, the removing increased up to 90% after 8 days.

Downloads

Download data is not yet available.

Downloads

Published

2017-07-17

How to Cite

Jasem, Nidaa Adil. “REDUCTION OF COD FROM SIMULATED WASTEWATER BY FABRICATED HYDROPHOBIC MEMBRANE”. Kufa Journal of Engineering, vol. 8, no. 2, July 2017, pp. 119-31, doi:10.30572/2018/KJE/821168.