EVALUATE AND RECTIFICATE THE PERFORMANCE OF THE SPIRAL PUMP OF THE HOLLY KARBALA SEWAGE TREATMENT STATION

Authors

  • Aymen Rashad Noor Civil Engineering Department, College of Engineering, University of Kufa

DOI:

https://doi.org/10.30572/2018/KJE/211337

Keywords:

SPIRAL PUMP, PUMP, TREATMENT STATION

Abstract

This paper evaluates the performance of the primary spiral (Archimedes) screw pump in the old sewage treatment station of the holly Karbala. This paper evaluates the pump according to its volumetric flow rate, determines the problems, diagnoses the defects, and finds the solutions. In addition, the paper suggests the optimum design for the pump. The results show a big effect of the side profile, pitch, and radius of the torque tube upon the discharge of the pump.

Downloads

Download data is not yet available.

Downloads

Published

2021-09-25

How to Cite

Rashad Noor, Aymen. “EVALUATE AND RECTIFICATE THE PERFORMANCE OF THE SPIRAL PUMP OF THE HOLLY KARBALA SEWAGE TREATMENT STATION”. Kufa Journal of Engineering, vol. 2, no. 1, Sept. 2021, pp. 1-19, doi:10.30572/2018/KJE/211337.