MODELLING OF PID CONTROLLER AND OPTIMIZATION FOR UPPER LIMB REHABILITATION ROBOT

Authors

  • Enas Hasan Ali Assistant Lecturer at Ibn Sina University of Medical and Pharmaceutical Sciences, Iraq
  • Meassar Al-Hussain Assistant Lecturer at Dep. of Medical Instrumentation Technical Eng. College of Medical Technical, Al-Farahidi University, Iraq
  • Omar M. Hussein Assistant Lecturer at Dep. of Medical Instrumentation Technical Eng. College of Medical Technical, Al-Farahidi University, Iraq
  • Ayat R Kamel Assistant Lecturer at Ibn Sina University of Medical and Pharmaceutical Sciences, Iraq

DOI:

https://doi.org/10.30572/2018/KJE/170408

Keywords:

Robotic, Upper limp exoskeletons, Anthropometric, MATLAB, PID Tuning

Abstract

This paper presents a lightweight, wearable exoskeletal robot designed for upper extremity stroke rehabilitation. The device aids in repetitive treatment sessions, both at home and in clinical settings, by enhancing mobility and enabling patients to perform everyday tasks while standing or sitting. With a focus on intensive physical rehabilitation, this eight-degree-of-freedom exoskeleton incorporates a sophisticated control system and integrated biofeedback to improve the efficiency and effectiveness of therapy This paper presents a lightweight, wearable exoskeletal robot designed for upper extremity stroke rehabilitation. The device aids in repetitive treatment sessions, both at home and in clinical settings, by enhancing mobility and enabling patients to perform everyday tasks while standing or sitting. With a focus on intensive physical rehabilitation. The MATLAB system identification technique is used to build the joint's actuator model, enabling an examination of the exoskeleton's dynamics. The exoskeleton is modelled in three dimensions using SolidWorks software. In addition, SimMechanics is used as a simulation approach. Afterwards, we verify the model through simulation, integrate it with a MATLAB-Simulink control model, and test it in payload. The results suggest that the model effectively verifies the controller's ability to accurately follow the exoskeleton's trajectory in simulation. The RMS inaccuracy of the joint angle is minimal and closely approximates the desired input of the joint showing the maximum RMS value 2.2 deg in shoulder internal/external rotation.

Downloads

Download data is not yet available.

References

Aouf, A., Boussaid, L. and Sakly, A. (2017) ‘A PSO algorithm applied to a PID controller for motion mobile robot in a complex dynamic environment’, in, pp. 1–7. doi:10.1109/ICEMIS.2017.8273012.

Brose, S.W. et al. (2010) ‘The role of assistive robotics in the lives of persons with disability.’, American journal of physical medicine & rehabilitation, 89(6), pp. 509–521. doi:10.1097/PHM.0b013e3181cf569b.

Centers for Disease Control and Prevention (no date). Available at: http://www.cdc.gov/niosh/topics/anthropometry/. (Accessed: 9 January 2014).

Colombo, R. et al. (2005) ‘Robotic techniques for upper limb evaluation and rehabilitation of stroke patients.’, IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society, 13(3), pp. 311–324. doi:10.1109/TNSRE.2005.848352.

Dodson, C.C. and Cordasco, F.A. (2008) ‘Anterior Glenohumeral Joint Dislocations’, Orthopedic Clinics of North America, 39(4), pp. 507–518. doi:https://doi.org/10.1016/j.ocl.2008.06.001.

Emad Sadiq, S. et al. (2025) ‘Free Vibration Analysis in Innovative 3D Printing Sandwich Panaels for Aircraft Structure’, Kufa Journal of Engineering, 16(1), pp. 265–282. doi:10.30572/2018/KJE/160116.

Flores-Ortiz, R., Malta, D.C. and Velasquez-Melendez, G. (2019) ‘Adult body weight trends in 27 urban populations of Brazil from 2006 to 2016: A population-based study.’, PloS one, 14(3), p. e0213254. doi:10.1371/journal.pone.0213254.

Gnasso, R. et al. (2023) ‘Robotic-Assisted Rehabilitation for Post-Stroke Shoulder Pain: A Systematic Review.’, Sensors (Basel, Switzerland), 23(19). doi:10.3390/s23198239.

Gopura, R.A.R.C., Kiguchi, K. and Bandara, S. (2011) ‘A brief review on upper extremity robotic exoskeleton systems’, in, pp. 346–351. doi:10.1109/ICIINFS.2011.6038092.

Gopura, R.A.R.C., Kiguchi, K. and Li, Y. (2009) ‘SUEFUL-7: A 7DOF upper-limb exoskeleton robot with muscle-model-oriented EMG-based control’, in 2009 IEEE/RSJ International Conference on Intelligent Robots and Systems, pp. 1126–1131. doi:10.1109/IROS.2009.5353935.

Gresham, G.E. et al. (1997) ‘American Heart Association Prevention Conference. IV. Prevention and Rehabilitation of Stroke. Rehabilitation.’, Stroke. United States, pp. 1522–1526. doi:10.1161/01.str.28.7.1522.

Hogan, N. et al. (1992) ‘MIT-MANUS: a workstation for manual therapy and training. I’, in [1992] Proceedings IEEE International Workshop on Robot and Human Communication, pp. 161–165. doi:10.1109/ROMAN.1992.253895.

Ismael, H.H. et al. (2025) ‘Artificial Intelligence in Robotic Manipulators: Exploring Object Detection and Grasping Innovations’, Kufa Journal of Engineering, 16(1), pp. 136–159. doi:10.30572/2018/KJE/160109.

Jaber, F.F. (2025) ‘Pid Controller for Speed Control of Pmsm Based on Mayfly Optimization Algorithm’, Kufa Journal of Engineering, 16(1), pp. 104–120. doi:10.30572/2018/KJE/160107.

John J. Craig (2005) Introduction to RoboticsMechanics and Control. Third Edit. United States of America. Available at: http://alvarestech.com/temp/RoboAseaIRB6S2-Fiat/httplinuxcnc.orgdocshtmlmanman9kins.9.html-introducaoarobotica-mecanicacontrole.pdf.

Joyo, M.K.; Raza, Y.; Ahmed, S.F.; Billah, M.M.; Kadir, K.; Naidu, K.; Ali, A.; Mohd Yusof, Z. (2019) Optimized Proportional-Integral-Derivative Controller for Upper Limb Rehabilitation Robot. Electronics 2019, 8, 826. https://doi.org/10.3390/electronics8080826

Kiguchi, K. et al. (2003) ‘An exoskeletal robot for human shoulder joint motion assist’, IEEE/ASME Transactions on Mechatronics, 8(1), pp. 125–135. doi:10.1109/TMECH.2003.809168.

Mao, Y. and Agrawal, S.K. (2012) ‘Transition from mechanical arm to human arm with CAREX: A cable driven ARm EXoskeleton (CAREX) for neural rehabilitation’, in 2012 IEEE International Conference on Robotics and Automation, pp. 2457–2462. doi:10.1109/ICRA.2012.6224906.

Renfrew, A. (2004) ‘Book Review: Introduction to Robotics: Mechanics and Control’, International Journal of Electrical Engineering & Education, 41(4), p. 388. doi:10.7227/IJEEE.41.4.11.

Roderick, S., Liszka, M. and Carignan, C. (2005) ‘Design of an arm exoskeleton with scapula motion for shoulder rehabilitation’, in ICAR ’05. Proceedings., 12th International Conference on Advanced Robotics, 2005., pp. 524–531. doi:10.1109/ICAR.2005.1507459.

Shneen, S.W. et al. (2025) ‘Artificial Neural Network (Ann) Based Proportional Integral Derivative (Pid) for Arm Rehabilitation Device’, Kufa Journal of Engineering, 16(1), pp. 80–103. doi:10.30572/2018/KJE/160106.

Zeiaee, A. et al. (2019) ‘Kinematic Design Optimization of an Eight Degree-of-Freedom Upper-Limb Exoskeleton’, Robotica, 37(12), pp. 2073–2086. doi:10.1017/S0263574719001085.

Downloads

Published

2026-11-14

How to Cite

Ali, Enas Hasan, et al. “MODELLING OF PID CONTROLLER AND OPTIMIZATION FOR UPPER LIMB REHABILITATION ROBOT”. Kufa Journal of Engineering, vol. 17, no. 4, Nov. 2026, pp. 120-36, https://doi.org/10.30572/2018/KJE/170408.

Share