AN EXPERIMENTAL STUDY FOR THE EFFECT OF CAPILLARY TUBE DIAMETER ON REFRIGERATOR PERFORMANCE WITH NEW ALTERNATIVE REFRIGERANT MIXTURE TO R134A

Authors

  • Ali K. Al-Sayyab Thermal Mechanical Engineering Department, College/of Technical Engineering-Basra, Southern Technical University

DOI:

https://doi.org/10.30572/2018/KJE/090203

Keywords:

Capillary Tube, refrigerant mixture, refrigerat

Abstract

In this work, the effect of capillary tube diameter on refrigerator performance is studied for refrigerants R134a, R290, R600a and its mixture which named: RMix1(70%R134a,20%R290,10%R600a), RMix2(70%R134a,10%R290,20%R600a), RMix3.(50%R134a,20%R290,30%R600a), RMix4 (60%R134a,20%R290,20%R600a). The three adopted capillary tubes diameter are 1.4 mm, 1.8 mm and 2.2 mm, named capillary1, capillary2 and capillary3 respectively. The experimental work show  that, the refrigerator operates in  2.2 mm capillary tube's diameter with R134a  gives the highest COP from other refrigerants with the same diameter, where the performance of refrigerator with capillary tube of 1.4 mm and alternative ozone friendly refrigerant  RMix2 give 1.3% COP reduction from base case of R134a .

Downloads

Download data is not yet available.

Downloads

Published

2018-04-02

How to Cite

Al-Sayyab, Ali. “AN EXPERIMENTAL STUDY FOR THE EFFECT OF CAPILLARY TUBE DIAMETER ON REFRIGERATOR PERFORMANCE WITH NEW ALTERNATIVE REFRIGERANT MIXTURE TO R134A”. Kufa Journal of Engineering, vol. 9, no. 2, Apr. 2018, pp. 31-44, doi:10.30572/2018/KJE/090203.

Similar Articles

1 2 3 > >> 

You may also start an advanced similarity search for this article.