The Evaluating the sensitivity of Hexagon OBTI test and Kastel-Meyer test by detection of human blood
DOI:
https://doi.org/10.36320/ajb/v16.i1.13363Keywords:
Hexagon OBTI. Kastel-Meyer. Detection of human blood.Abstract
The Hexagon OBTI test is a commercial kit made for the purpose of forensically identifying human blood. The test process is straightforward and does not need for a lab environment. To reduce between-sampling variation, all samples (blood) were taken from the researcher, a healthy male who was 33 at the time of collection. Blood thinners were created using liquid blood supplies and deionized water in the following dilutions: 1:10, 1:100, 1:1000, 1:100,000, 1:1,000,000, 1:10000000, and 1:100000000. The samples were analyzed by Hexagon OBTI and Kastel-Meyer, and the findings of both tests were positive up to a dilution of 1:1000 in the case of the former and 1:1000000 in the case of the latter. The result was a more sensitive OBTI test than Kastel-Meyer , the OBTI test is therefore suitable for identification of human blood at crime scenes
Downloads
References
Jackson, A.R.W. & Jackson, J.M. (2010). Forensic Science, 3rd Edition. Essex, Pearson Education Ltd.
Frumkin D, Wasserstrom A, Davidson A, et al.Authentication of forensic DNA samples. Forensic SciInt Genet 2010; 4(2): 95–103. DOI: https://doi.org/10.1016/j.fsigen.2009.06.009
Muro CK, Doty KC, de Souza Fernandes L, et al.Forensic body fluid identification and differentiation byRaman spectroscopy. Forensic Chem 2016; 1: 31–38. DOI: https://doi.org/10.1016/j.forc.2016.06.003
Hochmeister, M.; Sparkes, R.; Rudin, O.; Gehrig, C.; Schmidt, L., Cordier, A.; Dirnhofer, R. Evaluation of an Immunochromatographic 1-step Test for the Forensic Identification of Human Blood. Presented at the 50th annual meeting of the American Academy of Forensic Sciences, San Francisco, CA, 1998. DOI: https://doi.org/10.1520/JFS14516J
Hermon, D., Shpitzen, M., Oz, C., Glattstein, B., Azoury, M., & Gafny, R. (2003). The Use of the Hexagon OBTI Test for Detection of Human Blood at Crime Scenes and on Items of Evidence Part 1: Validation Studies and Implementation. Journal of Forensic Identification, 53(5), 566-575.
Cox, M. A. Study of the Sensitivity and Specificity of Four Presumptive Tests for Blood. J. For. Sci. 1991, 36 (5), 1503- 1511. DOI: https://doi.org/10.1520/JFS13170J
https://www.bluestar-forensic.com/medias/ documentationfile/bluestar_obti_verification_report.pdf
K. Virkler, I.K. Lednev, Analysis of body fluids for forensic purposes: from laboratory testing to non-destructive rapid confirmatory identification at a crime scene, Forensic Sci. Int. 188 (1–3) (2009) 1–17. DOI: https://doi.org/10.1016/j.forsciint.2009.02.013
S.S. Tobe, N. Watson, N.N. Dae´id, Evaluation of six presumptive tests for blood, their specificity, sensitivity, and effect on high molecular-weight DNA, J. Forensic Sci. 52 (1) (2007) 102–109. DOI: https://doi.org/10.1111/j.1556-4029.2006.00324.x
M. Grodsky, K. Wright, P.L. Kirk, Simplified preliminary blood testing. An improved technique and a comparative study of methods, J. Crim. Law Criminol. Police Sci. 42 (1) (1951) 95–104. DOI: https://doi.org/10.2307/1140307
Idris, B., & Goodwin, W. H. (2022). Evaluating the sensitivity of presumptive and confirmatory tests for body fluids. Forensic Science International: Genetics Supplement Series, 8, 276-278. DOI: https://doi.org/10.1016/j.fsigss.2022.10.061
Downloads
Published
Issue
Section
License
Copyright (c) 2024 Yousif M. Jebur

This work is licensed under a Creative Commons Attribution 4.0 International License.
which allows users to copy, create extracts, abstracts, and new works from the Article, alter and revise the Article, and make commercial use of the Article (including reuse and/or resale of the Article by commercial entities), provided the user gives appropriate credit (with a link to the formal publication through the relevant DOI), provides a link to the license, indicates if changes were made and the licensor is not represented as endorsing the use made of the work.